Part Number Hot Search : 
74LS37 IC16F 54FCT AM29F800 XBA170S 0STRR 257QG BU9728A
Product Description
Full Text Search
 

To Download B84114D0000L110 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 EMC filters
2-line filters
SIFI-D for high insertion loss
Rated current 1 to 10 A
Series/Type: Date: B84114D January 2006
EPCOS AG 2006. Reproduction, publication and dissemination of this data sheet and the information contained therein without EPCOS' prior express consent is prohibited.
2-line filters SIFI-D for high insertion loss
Power line filters for 1-phase systems Rated voltage 250 V DC/AC, 50/60 Hz Rated current 1 to 10 A Construction
2-line filters
Metal case
Polyurethane potting (UL 94 V-0)
B84114D
Features

Compact design
Optimized leakage current
Cost-optimized construction
Also for assembly on top-hat rails
ENEC10, UL and CSA approval
Applications
Switch-mode power supplies in
- industrial electronics - telecommunications - data systems - medical equipment DC applications Case styles and terminal styles Case style A Case style B Case style K Case style L Marking Marking on component: Manufacturer's logo, ordering code, rated voltage, rated current, rated temperature, climatic category, date code Minimum marking on packaging: Manufacturer's logo, ordering code Tab connectors on face ends, lateral fixing lugs. Particularly suitable for mounting on a shielding wall. Tab connectors on face ends, fixing lugs on face ends. IEC connector as per IEC 60320 C 14 on line side, tab connectors on load side, mounting holes with metric thread. Litz wires on face ends, fixing lugs on face ends
Please read Cautions and warnings and
Important notes at the end of this document.
2
01/06
2-line filters SIFI-D for high insertion loss
Circuit diagram
LINE L LOAD L'
B84114D
N
N'
SSB0238-A
Technical data and measuring conditions Rated voltage VR Rated current IR Test voltage Vtest Leakage current lleak Climatic category (IEC 60068-1) Approvals 250 V DC/AC, 50/60 Hz Referred to 40 C ambient temperature 1414 V DC, 2 s (line/line) 2700 V DC, 2 s (lines/case) At 230 V AC, 50 Hz 25/085/21 (-25 C/+85 C/21 days damp heat test) EN 133200, UL 1283, CSA C22.2 No.8
Please read Cautions and warnings and
Important notes at the end of this document.
3
01/06
2-line filters SIFI-D for high insertion loss
Characteristics and ordering codes IR A 1 2 x 0.47 F (X2) + 2 x 4700 pF (Y2) 2 x 0.47 F (X2) + 2 x 4700 pF (Y2) 2 x 0.47 F (X2) + 2 x 4700 pF (Y2) 2 x 0.47 F (X2) + 2 x 4700 pF (Y2) 2 x 0.68 F (X2) + 2 x 4700 pF (Y2) CR LR mH 2x 5.6 Ileak mA Case Approx. Ordering code style weight g 150 150 210 150 150 150 150 150 150 210 150 230 230 290 230 420 420 420 B84114D0000A010 B84114D0000B010 B84114D0000K010 B84114D0000L010
B84114D
Mounting plate for top-hat rail (ordering code) -- C62122A0132B092 -- --
VR = 250 V DC/AC, 50/60 Hz < 0.5 A B K L < 0.5 A B L < 0.5 A B K L < 0.5 A B K L < 0.5 A B L
2
2x 5.6 2x 5.6
B84114D0000A020 -- B84114D0000B020 C62122A0132B092 B84114D0000L020 -- B84114D0000A030 B84114D0000B030 B84114D0000K030 B84114D0000L030 B84114D0000A060 B84114D0000B060 B84114D0000K060 B84114D0000L060 -- C62122A0132B092 -- -- -- C62122A0132B093 -- --
3
6
2x 4.7
10
2x 4.7
B84114D0000A110 -- B84114D0000B110 C62122A0132B094 B84114D0000L110 --
Please read Cautions and warnings and
Important notes at the end of this document.
4
01/06
2-line filters SIFI-D for high insertion loss
Case styles and dimensions Case style A B K L A B L A B K L A B K L A B L IR A 1 1 1 1 2 2 2 3 3 3 3 6 6 6 6 10 10 10 50.8 50.8 50.8 50.8 31.5 31.5 -- -- 60.4 -- -- -- 70 -- -- -- 63.5 63.5 79.5 63.5 -- 74.7 -- 74.7 -- 84.5 -- 84.5 89.5 89.5 -- -- 28.6 28.6 32 28.6 20 20 -- -- Dimensions (mm) b2 b3 b4 b1
B84114D
l1
l2
l3
l4
h1
h2
Litz mm2 -- -- -- 0.82 -- -- 0.82 -- -- -- 0.82 -- -- -- 0.82
Style 1015 -- -- -- AWG18 -- -- AWG18 -- -- -- AWG18 -- -- -- AWG18
50.8 31.5 60.4 70 50.8 31.5 -- -- 50.8 -- -- -- 50.8 50.8 50.8 50.8 50.8 50.8 50.8 50.8 31.5 31.5 -- -- 31.5 31.5 -- -- 60.4 -- -- -- 60.4 -- -- -- 70 -- -- -- 70 -- -- --
63.5 -- -- 89.5 28.6 20 63.5 74.7 84.5 89.5 28.6 20 63.5 74.7 84.5 -- 28.6 -- 63.5 63.5 79.5 63.5 75.5 75.5 92.5 75.5 -- 74.7 -- 74.7 -- 87.1 -- 87.1 -- 84.5 -- 84.5 -- 97 -- 97 89.5 89.5 -- -- 101.5 101.5 -- -- 28.6 28.6 32 28.6 31.8 31.8 32 31.8 20 20 -- -- 20 20 -- --
50.8 --
--
--
See dimensional drawing See dimensional drawing 92 103.1 113 -- 44.5 --
1.35
AWG16
Please read Cautions and warnings and
Important notes at the end of this document.
5
01/06
2-line filters SIFI-D for high insertion loss
Case styles A 1 ... 6 A (B84114D0000A010 ... A060)
b1 b2
B84114D
10 A (B84114D0000A110)
50.8 31.5
0.8 h1
Tab connector A6.3 x 0.8
Tab connector A6.3 x 0.8 o4.7
o4.7
50.8 118
1 4
0.8
b3 b4
SSB0531-6-E
60.4 70
SSB0269-5-E
Case styles B
1 ... 6 A (B84114D0000B010 ... B060)
b1 b2
10 A (B84114D0000B110)
50.8 31.5
Tab connector A6.3 x 0.8 o4.7
0.8
Tab connector A6.3 x 0.8
103.1
0.8
113
SSB0528-L-E
o4.7
Please read Cautions and warnings and
Important notes at the end of this document.
SSB0268-W-E
6
01/06
118
92
4
1
2
3
28.5
h2
h1
44.5
92
28.5
h2
44.5
2-line filters SIFI-D for high insertion loss
Case style K
b1
M4
16 h1
3.41
B84114D
Case style L
101
161
40
Tab connector A6.3 x 0.8
BN BU
13
41 b1
105+15 105+15
1
1
3
Panel cutout
o4.5
2
31.5
28.5 400.2
20.5
GNYE
6 _2
3
BN
BU
19
SSB0255-Z-E
SSB0529-U-E
Please read Cautions and warnings and
Important notes at the end of this document.
7
01/06
6 _2
o4.7
0.8
h1
2-line filters SIFI-D for high insertion loss
Insertion loss (typical values at Z = 50 ) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) Filters for 1, 2 and 3 A
100 dB B84114D0000*010 B84114D0000*020 B84114D0000*030 80
SSB0265-7
B84114D
Filters for 6 A
100 dB B84114D0000*060
80
SSB0266-F
60
60
40
40
20
20
0 10 4
10 5
10 6
10 7
Hz 10 8 f
0 10 4
10 5
10 6
10 7
Hz 10 8 f
Filters for 10 A
100 dB B84114D0000*110 80
SSB0267-N
60
40
20
0 10 4
10 5
10 6
10 7
Hz 10 8 f
Please read Cautions and warnings and
Important notes at the end of this document.
8
01/06
EMC filters Cautions and warnings
Important information Please read all safety and warning notes carefully before installing the EMC filter and putting it into operation (see ). The same applies to the warning signs on the filter. Please ensure that the signs are not removed nor their legibility impaired by external influences. Death, serious bodily injury and substantial material damage to equipment may occur if the appro priate safety measures are not carried out or the warnings in the text are not observed. Using according to the terms The EMC filters may be used only for their intended application within the specified values in low voltage networks in compliance with the instructions given in the data sheets and the data book. The conditions at the place of application must comply with all specifications for the filter used. Warnings
It shall be ensured that only qualified persons (electricity specialists) are engaged on work such

as planning, assembly, installation, operation, repair and maintenance. They must be provided with the corresponding documentation. Danger of electric shock. EMC filters contain components that store an electric charge. Danger ous voltages can continue to exist at the filter terminals for longer than five minutes even after the power has been switched off. The protective earth connections shall be the first to be made when the EMC filter is installed and the last to be disconnected. Depending on the magnitude of the leakage currents, the particular specifications for making the protective-earth connection must be observed. Impermissible overloading of the EMC filter, such as impermissible voltages at higher frequen cies that may cause resonances etc. can lead to destruction of the filter housing. EMC filters must be protected in the application against impermissible exceeding of the rated currents by suitable overcurrent protective.
9
01/06
EMC filters Important notes
The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of passive electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of a passive electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of a passive electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as "hazardous"). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, EPCOS-Jones, Baoke, CeraDiode, CSSP, MLSC, PhaseCap, PhaseMod, SIFI, SIKOREL, SilverCap, SIMID, SIOV, SIP5D, SIP5K, UltraCap, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks.
10
01/06


▲Up To Search▲   

 
Price & Availability of B84114D0000L110

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X